1. Skip to Menu
  2. Skip to Content
  3. Skip to Footer

 

Order Example 6: FILLCONTROL Control P
   
  Automatic machine control

Constant quality parameters
Transfer of molds
Identical part quality
Example:
  • Control of the quality parameters of one large-area part
  • 1 cavity temperature sensor (shear rate, shear stree, mold temperature at 1 bar)
    Automatic switchover to holding pressure
  • 1 cavity pressure sensor (shear rate, shear stress, compression, mold temperature at 1 bar)
 
 Item  Quantity
 Module-Type
 Description
1
1
 7080A Control P
 Software module for automatic machine control, incl. BlueLine Core type 8280C
 and connecting cable type 1250A5-Arbg RS232
2 1  7080A Monitor  Software module for monitoring and control of the injection molding process
3
1  9021A  Mounting device for BlueLine Core type 8280C 
4 1  5070A-2p2T  BlueLine multi-channel amplifier for 2 temperature and 2 pressure channels
5 1  1280A5  BlueLine Hybrid Bus connecting cable, l = 5 m
6 2  1141A2  Connecting cable (temperature), l = 2 m
7 1  4004C0.2-101  Miniature cavity temperature sensor
8 1  4561B  Mounting / extraction tool for cavity temperature sensors
9 1  1041A2  Connecting cable (pressure), l = 2 m
10 1  6002B0.4-102  PRIASAFE®cavity pressure sensor
11 1  6562B  Mounting tool for mounting nuts
12 1  6561A  Mounting / extraction tool for cavity pressure sensors
13 1  1282A2  Installation kit incl. control cabinet feed through type 1282A and BlueLine Hybrid
 Bus cable type 1280A2
14 1  8980C  BlueLine I/O Master, Interface for easy connecting of digital alarm and switching
 signals to the machine respectively to the peripherals