Fillcontrol Monitor

FILLCONTROL Monitor is a comprehensive process monitoring module and serves as the basis for all PRIAMUS® systems. It offers the possibility of simple bad part separation such as the removal of individual bad parts with the help of individual alarm signals

In addition, FILLCONTROL Monitor offers the opportunity of detecting the melt position in the cavity, switching over to holding pressure automatically or via switching level and monitoring viscosities.

The quality-dependent monitoring parameters are divided into warning, intervention and alarm limits.

Application
Good / bad part separation
Switchover to holding pressure via switching level
Automatic switchover to holding pressure
Viscosity monitoring
Application Problem Example Solution
General Parts are not filled Cable connector Monitoring the pressure level
Coinjection Uncontrolled filling Food container Monitoring the sheer rate
Family molds Different length of flow paths Model kits Monitoring the individual cavities